CONTEC CMS6000 Cms5100 Small Size Patient Monitor For ICU/Hospital/Ambulance
Introduction
Cms5100 Patient Monitor is a medical device used to monitor the physical condition of patients. It can contain one or more sensors, processing components, display devices (sometimes called "monitors"), and communication links for displaying or recording results in other locations through the surveillance network. Cms5100 Patient Monitor has abundant monitoring functions and is used for monitoring of adult, pediatric and neonate.
Features
1)8" color TFT display
2)multi-language interface
3)Cms5100 Patient Monitor is suitable for adult, pediatric and neonatal patient
4)Basic parameters (ECG, SpO2, NIBP)
5)Durable case for bedside monitoring and transport
6)Audible and visual alarms with adjustable alarm ranges
Performance
▲ECG
Lead mode |
3-lead or 5-lead |
Lead selection |
I, II, III, aVR, aVL, aVF, V |
Waveform |
5-lead, 2-channel |
3-lead, 1-channel | |
Gain |
2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV |
Scan speed |
12.5mm/s, 25 mm/s, 50 mm/s |
HR |
|
Measurement and alarm range |
15~350bpm |
Accuracy |
±1% or ±1bpm, whichever is greater |
Alarm accuracy |
± 2 bpm |
Resolution |
1 bpm |
ST-segment monitoring |
|
Measurement and alarm range |
-2.0mV~+2.0mV |
Accuracy |
-0.8mV~+0.8mV ±0.04mv or ±10%, whichever is greater |
Other range |
unspecified |
Arrhythmia analysis |
ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC |
Pacemaker |
yes |
RESPIRATION |
|
Method |
R-F(RA-LL) Impedance |
Respiration rate |
|
Measurement and alarm range |
0~150rpm |
Resolution |
1 rpm |
Measurement accuracy |
±2 rpm |
Alarm accuracy |
±3 rpm |
Apnea alarm |
10~40s |
Scan speed |
6.25 mm/s, 12.5 mm/s, 25 mm/s |
▲NIBP
Method |
Oscillometry |
Mode |
Manual/AUTO/STAT |
Measurement interval in AUTO mode |
1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes |
Measurement period in STAT mode |
5 minutes |
Measurement and alarm range |
10 ~ 270 mmHg |
Resolution |
1 mmHg |
Cuff pressure accuracy |
±3 mmHg |
Measurement accuracy |
|
Maximal mean deviation |
±5 mmHg |
Maximal standard deviation |
8mmHg |
Over-pressure protection |
|
Adult mode |
297±3 mmHg |
Pediatric mode |
240±3 mmHg |
Neonatal mode |
147±3 mmHg |
▲SpO2
Measurement and alarm range |
0 ~ 100% |
Resolution |
1% |
Measurement accuracy |
70%~100%: ±2%; |
0%~69%: unspecified | |
PR |
|
Measurement and alarm range |
30 ~ 250 bpm |
Measurement accuracy |
±2 bpm or ±2%, whichever is greater |
TEMP |
|
Channel |
dual-channel |
Measurement and alarm range |
0 ~ 50℃ |
Resolution |
0.1 ℃ |
Accuracy |
±0.1 ℃ |
▲EtCO2
Method |
Sidestream or Mainstream |
Measurement range for CO2 |
0 ~ 150mmHg |
Resolution for CO2 |
0.1 mm Hg: 0 ~ 69 mm Hg |
0.25 mm Hg: 70 ~ 150 mm Hg | |
Accuracy for CO2 |
0 ~ 40 mm Hg: ±2 mm Hg |
41 ~ 70 mm Hg: ±5% | |
71 ~ 100 mm Hg: ±8% | |
101 ~ 150 mm Hg: ±10% | |
AwRR range |
2~150 rpm |
AwRR accuracy |
±1 rpm |
Apnea alarm |
yes |
IBP |
|
Channel |
dual-channel |
Label |
ART, PA, CVP, RAP, LAP, ICP, P1, P2 |
Measurement and alarm range |
-10~300 mm Hg |
Resolution |
1 mmHg |
Accuracy |
±2% or 1mm Hg, whichever is greater |
Power supply |
100-240V~, 50/60Hz |
Safety classification |
Class I, type CF defibrillation-proof applied part |
Accessories
+Adult fingertip SpO2 probe (5-pin);
+Adult NIBP cuff;
+NIBP extension tube;
+ECG lead cable;
+ECG electrode;
+Temperature probe;
+Power adapter;
+Power cord;
+User Manual;
Physical characteristic
Dimension: 235 mm(L) × 141 mm(W) × 222 mm(H)
Weight: 2.5 Kg
More Products
FAQ
Q: Can you print rhythm strips/reports?
A: Sorry, this unit cannot print rhythm strips/reports.
Q: Does this product come with a warranty?
A: Yes, All of the products have 30 days to return and money back provided, If you have any technical problems, we will provide professional technicians for you.
Q: Does it come with a temperature probe and can you buy a larger BP cuff
A: Yes, it comes with a temperature probe, the machine usually comes with an adult BP cuff, if you need please email us. Hope this can help you.
Q: What is the AC power supply of this item?
A: This machine is a wide power supply, can be used in any country, we will arrange the correct power cord according to your address.
Q: Does it work without having to use the EKG part?
A: No.
Q: I have this product available in usa or have to ask hong kong?how long to delay sending miami? A: shipping from IL. The USA. shipping same day or next business day(Monday to Friday), after received cleared payment order from Amazon.com before 4:00 pm Chicago time zone (Monday to Friday).
Q: Can this do continous pulse ox?
A: YES, IT GO WITH AN ADULT SPO2 PROBE ,and can record the data .attention: only fit for adults.
http://www.contecmedsystems.com/